##### Zeitspanne in Sekunden, ab der der Systemdienst einen Stromausfall annimmt. Nuetzlich, um sehr kurze Ausfaelle ignorieren zu koennen. Jeweils Master und Slave.
```yaml
apcupsd_master_onbatterydelay: 10
apcupsd_slave_onbatterydelay: 10
```
##### Durch die USV gemeldete Restkapazitaet in Prozent, ab der der Rechner heruntergefahren wird. Jeweils Master und Slave.
```yaml
apcupsd_master_batterylevel_for_shutdown: 50
apcupsd_slave_batterylevel_for_shutdown: 60
```
##### apcupsd will shutdown the system during a power failure when the remaining runtime on batteries as internally calculated by the UPS falls below the specified minutes. Jeweils Master und Slave.
```yaml
apcupsd_master_minutes_for_shutdown: 10
apcupsd_slave_minutes_for_shutdown: 11
```
##### Specifies when apcupsd should create the NOLOGON file to prevent users from logging on to the system. Jeweils Master und Slave.
```yaml
apcupsd_master_nologon_when_active: always
apcupsd_slave_nologon_when_active: always
```
##### Ist der Server MASTER, also ist die USV an diesem Computer angeschlossen, kann nur für einen PC "true" sein. Jeweils Master und Slave.
```yaml
apcupsd_nis_master: "true"
```
##### Wenn "true" ist dieser Host master, für alle anderen "false", das muss nicht explizit gesetzt werden.