Einbau neue USV (#325)

Co-authored-by: Michael Grote <michael.grote@posteo.de>
Reviewed-on: mg/ansible#325
Co-authored-by: mg <michael.grote@posteo.de>
Co-committed-by: mg <michael.grote@posteo.de>
This commit is contained in:
Michael Grote 2022-02-10 20:28:18 +01:00
parent 4cbb5d7aac
commit 5c8c608ab4
4 changed files with 62 additions and 63 deletions

View file

@ -93,8 +93,30 @@
env.client /usr/bin/fail2ban-client
env.config_dir /etc/fail2ban
user root
- name: apcupsd_ww
src: https://git.mgrote.net/mg/mirror-munin-contrib/raw/branch/master/plugins/power/apcupsd_ww
- name: apcupsd_pwr
src: https://git.mgrote.net/mg/munin-plugins/raw/branch/master/extern/apcupsd_pwr
config: |
[apcupsd_pwr]
env.ups_model APC-BX950U-GR
### mgrote.apt_manage_sources
manage_sources_apt_proxy: ""
# Ansible Variablen
### sudo
sudo: false
### mgrote.apcupsd
apcupsd_master_onbatterydelay: 10
apcupsd_master_batterylevel_for_shutdown: 50
apcupsd_master_minutes_for_shutdown: 10
apcupsd_master_nologon_when_active: "disable"
apcupsd_nis_master: true
apcupsd_nis_master_hostname: pve2.grote.lan
apcupsd_nis_master_listen_ip: 0.0.0.0
apcupsd_nis_master_listen_port: 3551
apcupsd_ups_name: APC-BX950U-GR

View file

@ -21,3 +21,5 @@
tags: "r8152" }
- { role: mgrote.proxmox_bind_mounts,
tags: "bindmounts" }
- { role: mgrote.apcupsd,
tags: "apcupsd" }

View file

@ -3,7 +3,7 @@
### Beschreibung
* Installiert apcupsd.
* Auf einem PC als "Master", hier ist die USV per USB angeschlossen.
* Auf allen anderen PCs als "Slave", diese OCs pollen alle n Sekunden den Master.
* Auf allen anderen PCs als "Slave", diese OCs pollen alle <n> Sekunden den Master.
* Benoetigt mgrote.postfix.
* Getestet mit: APC-BX950U-GR
@ -14,55 +14,7 @@
### getestet auf
- [x] ProxMox 6.1
- [x] ProxMox 7
### Variablen + Defaults
##### Zeitspanne in Sekunden, ab der der Systemdienst einen Stromausfall annimmt. Nuetzlich, um sehr kurze Ausfaelle ignorieren zu koennen. Jeweils Master und Slave.
```yaml
apcupsd_master_onbatterydelay: 10
apcupsd_slave_onbatterydelay: 10
```
##### Durch die USV gemeldete Restkapazitaet in Prozent, ab der der Rechner heruntergefahren wird. Jeweils Master und Slave.
```yaml
apcupsd_master_batterylevel_for_shutdown: 50
apcupsd_slave_batterylevel_for_shutdown: 60
```
##### apcupsd will shutdown the system during a power failure when the remaining runtime on batteries as internally calculated by the UPS falls below the specified minutes. Jeweils Master und Slave.
```yaml
apcupsd_master_minutes_for_shutdown: 10
apcupsd_slave_minutes_for_shutdown: 11
```
##### Specifies when apcupsd should create the NOLOGON file to prevent users from logging on to the system. Jeweils Master und Slave.
```yaml
apcupsd_master_nologon_when_active: always
apcupsd_slave_nologon_when_active: always
```
##### Ist der Server MASTER, also ist die USV an diesem Computer angeschlossen, kann nur für einen PC "true" sein. Jeweils Master und Slave.
```yaml
apcupsd_nis_master: "true"
```
##### Wenn "true" ist dieser Host master, für alle anderen "false", das muss nicht explizit gesetzt werden.
```yaml
apcupsd_nis_master: on
```
##### FQDN oder IP des "master"
```yaml
apcupsd_nis_master_hostname: pve2.grote.lan
```
##### Interface auf dem der "Master" erreichbar ist.
```yaml
apcupsd_nis_master_listen_ip: 0.0.0.0
```
##### Post auf dem der "Master" erreichbar ist.
```yaml
apcupsd_nis_master_listen_port: 3551
```
##### Name der USV
```yaml
apcupsd_ups_name: APC-BX950U-GR
```
- siehe [defaults/main.yml](./defaults/main.yml)

View file

@ -1,17 +1,40 @@
---
apcupsd_master_onbatterydelay: 10
apcupsd_master_batterylevel_for_shutdown: 50
apcupsd_master_minutes_for_shutdown: 10
apcupsd_master_nologon_when_active: always
## Values: http://www.apcupsd.org/manual/manual.html
apcupsd_slave_onbatterydelay: 10
apcupsd_slave_batterylevel_for_shutdown: 60
apcupsd_slave_minutes_for_shutdown: 11
apcupsd_slave_nologon_when_active: always
## Master
# Wenn "true" ist dieser Host master.
apcupsd_nis_master: true
# Interface auf dem der "Master" erreichbar ist.
apcupsd_nis_master_listen_ip: 0.0.0.0
# Post auf dem der "Master" erreichbar ist.
apcupsd_nis_master_listen_port: 3551
# Name der USV
apcupsd_ups_name: APC-BX950U-GR
## Slave
# Zeitspanne zwischen dem pollen
apcupsd_slave_polltime: 10 #in Sekunden
apcupsd_nis_master: on
## Master & Slave
# FQDN oder IP des "master"
apcupsd_nis_master_hostname: pve2.grote.lan
apcupsd_nis_master_listen_ip: 0.0.0.0
apcupsd_nis_master_listen_port: 3551
apcupsd_ups_name: APC-BX950U-GR
# Zeitspanne in Sekunden, ab der der Systemdienst einen Stromausfall annimmt. Nuetzlich, um sehr kurze Ausfaelle ignorieren zu koennen.
apcupsd_master_onbatterydelay: 10
apcupsd_slave_onbatterydelay: 10
# Durch die USV gemeldete Restkapazitaet in Prozent, ab der der Rechner heruntergefahren wird.
apcupsd_master_batterylevel_for_shutdown: 50
apcupsd_slave_batterylevel_for_shutdown: 60
# apcupsd will shutdown the system during a power failure when the remaining runtime on batteries as internally calculated by the UPS falls below the specified minutes. Jeweils Master und Slave.
apcupsd_master_minutes_for_shutdown: 10
apcupsd_slave_minutes_for_shutdown: 11
# Specifies when apcupsd should create the NOLOGON file to prevent users from logging on to the system. Jeweils Master und Slave.
apcupsd_master_nologon_when_active: always
apcupsd_slave_nologon_when_active: always